TI-SKIN® Product Family

TI-SKIN® COMFORT

Dynamic phase-change insulation for residential and commercial buildings. Works in both summer and winter. EPBD IV compliant. Reduces HVAC load by up to 45%.

The Problem with Traditional Insulation

Static vs Dynamic Insulation

Traditional insulation is passive and static. It resists heat flow, but does nothing to moderate temperature swings or absorb thermal peaks. When the sun hits a wall at 2 PM, conventional mineral wool or EPS simply slows down the inevitable — the building still heats up, the HVAC system still works overtime.

TI-SKIN® COMFORT introduces dynamic thermal mass. The phase-change material absorbs excess heat energy during the day (melting), stores it as latent energy, and releases it at night (solidifying). The building envelope becomes a temperature buffer — not just a barrier.

Summer Mode

PCM absorbs solar heat gain during peak hours (melting phase), preventing interior temperature rise. As outdoor temperatures drop in evening, PCM releases stored heat outward — pre-cooling the envelope for the next day.

Winter Mode

During daylight hours, PCM absorbs solar gain through south-facing walls. As nighttime temperatures fall, PCM releases stored heat inward — reducing heating system demand during coldest hours.


Applications

Where COMFORT Performs Best

  • Residential buildings — new construction and deep energy retrofits
  • Office buildings — reducing afternoon cooling loads
  • Healthcare facilities — stable temperature zones without mechanical overcooling
  • Schools and universities — thermal comfort without acoustic disruption
  • Hotels and hospitality — silent, maintenance-free temperature stabilization
  • Historic buildings — non-invasive thermal upgrade without altering facades
  • Net Zero Energy Buildings (NZEBs) — EPBD IV compliance pathway
  • Passive House (Passivhaus) standard projects
Key Benefits
Up to 45% HVAC Load Reduction

Peak demand flattening reduces peak cooling/heating requirements, enabling smaller, lower-cost HVAC system sizing

Thermal Shift: 6–8 Hours

Delays peak indoor temperature by 6–8 hours — shifting peak demand from the hottest afternoon to cooler evening hours

Net Zero Compatible

Reduces building energy demand to levels compatible with PV solar supply — essential for NZEB classification under EPBD IV

1 m² = 1 Tree / Year

Each square meter of COMFORT installed delivers equivalent CO₂ offset to planting one tree per year, calculated over a 30-year product lifecycle


Technical Specifications — COMFORT Models

COMFORT 18°C
Warm-climate / cooling-dominant
Melt point18°C / 64°F
Latent energy145 j/g
Capacity>194 W/m²
PCM load83%
Thickness1.2 cm
Weight4.2 kg/m²
Cycles/year365
Lifespan>30 years
Fire index5 (450 max)
COMFORT 23°C ★ Best Seller
Mediterranean / Central European standard
Melt point23°C / 73°F
Latent energy190 j/g
Capacity>254 W/m²
PCM load83%
Thickness1.2 cm
Weight4.5 kg/m²
Cycles/year365
Lifespan>30 years
Energy savings35–45%+
COMFORT 28°C
Hot-climate / solar-intensive regions
Melt point28°C / 82°F
Latent energy215 j/g
Capacity>287 W/m²
PCM load83%
Thickness1.2 cm
Weight4.8 kg/m²
Cycles/year365
Lifespan>30 years
Fire index5 (450 max)

Physical format (all models): 1.2 cm × 48 cm × 122 cm. Pallet: 150 m² / 750 kg. 20' container: 1,500 m². 40' container: 3,000 m².


EU EPBD IV Directive — Building Renovation Wave

The Regulatory Mandate

55 Million Buildings Must Be Upgraded by 2033

The EU Energy Performance of Buildings Directive (EPBD IV), in force since 2024, mandates that all residential buildings achieve minimum energy performance class E by 2030 and class D by 2033. Approximately 55 million European buildings currently rated F or G must be upgraded.

TI-SKIN® COMFORT directly addresses this mandate: a 1.2 cm panel installation typically moves buildings up 1–2 energy classes, often converting F-rated buildings to D-rated without structural modifications. This makes it one of the highest-value compliance pathways per euro invested.

Market Size: The EU Building Renovation Wave represents €275+ billion in investment through 2030. TI-SKIN® COMFORT is positioned as a key enabling technology for deep renovations under Renovation Passports, with explicit support under the Social Climate Fund for social housing upgrades.

ROI vs. Heat Pump — Single-Family Home
MetricTI-SKIN COMFORTHeat Pump
Installation cost€2,400–4,800€8,000–15,000
Annual savings€600–900€800–1,200
Payback period4–6 years9–14 years
MaintenanceZeroAnnual service required
Lifespan30+ years15–20 years
CombinationCOMFORT + heat pump = 60–70% total energy reduction
Environmental Impact
1 m²
= 1 tree planted per year of CO₂ offset over 30-year lifecycle
100 m²
Typical home = forest of 100 trees, every year

Get Started

The Thinnest Path to EPBD IV Compliance

1.2 cm. No structural modification. No building permits in most EU jurisdictions. No maintenance. 30-year lifespan. TI-SKIN® COMFORT is the minimal-intervention maximum-impact solution for Europe's building renovation mandate.

← TI-SKIN Overview TI-SKIN COLD →